Show simple item record

contributor authorQayoum, Adnan
contributor authorPanigrahi, P. K.
date accessioned2017-05-09T01:20:04Z
date available2017-05-09T01:20:04Z
date issued2015
identifier issn0022-1481
identifier otherht_137_12_121004.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158596
description abstractThis investigation reports the combined effect of synthetic jet and a surfacemounted rib on heat transfer in a square crosssection channel flow. The rib height to hydraulic diameter ratio is equal to 0.1625. The Reynolds number of the channel has been set equal to 5500. The synthetic jet actuator has been operated at different actuation voltages with different amplitude modulation frequencies. At actuation voltage of 55 V, the maximum overall heat transfer is enhanced by 132.6% compared with smooth duct flow.
publisherThe American Society of Mechanical Engineers (ASME)
titleCombined Influence of Synthetic Jet and Surface Mounted Rib on Heat Transfer in a Square Channel
typeJournal Paper
journal volume137
journal issue12
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4030918
journal fristpage121004
journal lastpage121004
identifier eissn1528-8943
treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 012
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record