description abstractFor evaluating performance of finandtube heat exchangers under dehumidifying conditions, the recent lumped approach models are based on the enthalpy potential or equivalent dry bulb temperature. This study proposes a new lumped approach model based on the dry bulb temperature difference. The concept of dry bulb temperature was first presented by McQuiston for derivation of fin efficiency under dehumidifying conditions in 1975. This concept is simpler than the concepts of enthalpy potential and equivalent dry bulb temperature. Nevertheless, it cannot be found that this concept is applied to the finandtube heat exchangers. Moreover, this study also presents the finite circular fin method (FCFM) based on the dry bulb temperature and equivalent dry bulb temperature. The FCFM was first presented in our published literature but it was based on the enthalpy potential. The FCFM is done by dividing the finandtube heat exchanger into many small segments. Then, the segments are divided into three cases: fully dry condition, fully wet condition, and partially wet condition. From the results, the new lumped approach model based on dry bulb temperature gives a good result. It is the simplest method for evaluating heat transfer performance of finandtube heat exchangers under fully wet conditions. For the FCFM, the heat and mass transfer characteristics obtained by dry bulb temperature and equivalent dry bulb temperature are nearly the same as those obtained by the enthalpy potential. However, the heat and mass transfer characteristics by the FCFM based on equivalent dry bulb temperature are higher than those obtained by the FCFM based on dry bulb temperature. This is because of the effect of the nonconstant term in the two methods. The correlations applicable for both fully wet and partially wet conditions for the FCFMs based on equivalent dry bulb temperature and dry bulb temperature are proposed to describe the heat and mass transfer characteristics for the present plain fin configuration.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe New Mathematical Models for Plain Fin and Tube Heat Exchangers With Dehumidification
typeJournal Paper
journal volume137
journal issue3
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4029037
journal fristpage31801
journal lastpage31801
identifier eissn1528-8943
treeJournal of Heat Transfer:;2015:;volume( 137 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record