Show simple item record

contributor authorWaeytens, Julien
contributor authorChatellier, Patrice
contributor authorBourquin, Frأ©dأ©ric
date accessioned2017-05-09T01:19:08Z
date available2017-05-09T01:19:08Z
date issued2015
identifier issn0098-2202
identifier otherfe_137_09_091401.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158305
description abstractWe address the reconstruction of relevant twodimensional (2D) flows in drinking water networks, especially in key elements such as pipe junctions, in view of representative water quality simulations. From the optimal control theory, a specific inverse technique using few sensors and computational fluid dynamics (CFD) models has been developed. First, we determine the boundary velocities, i.e., the control parameters, by minimizing a data misfit functional. Then, knowing the boundary velocities, a direct solve of the flow model is performed to get the space–time cartography of the water flow. To reduce the number of control parameters to be determined and thus restrict the number of sensors, the spatial shape of the boundary velocities is considered as an a priori information given by the water pipes engineering literature. Thus, only the time evolution of the boundary velocities has to be determined. The whole numerical procedure proposed in this paper easily fits in a general purpose finite element software, featuring user's friendliness for a wide engineering audience. Two ways are investigated to reduce the computation time associated to the flow reconstruction. The adjoint framework is used in the minimization process. The reconstruction of the flow using coarse discretizations and simple flow models, instead of 2D Navier–Stokes equations, is studied. The influence of the flow modeling and of the dicretization on the quality of the reconstructed velocity is studied on two examples: a water pipe junction and a 200 m subsection from a French water network. In the water pipe junction, we show that at a Reynolds number of 200 a hybrid approach combining an unsteady Stokes reconstruction and a single direct Navier–Stokes simulation outperforms the algorithms based on a single model. In the network subsection, we obtain an L2 error less than 1% between the reference velocity based on Navier–Stokes equations (Reynolds number of 200) and the velocity reconstructed from Stokes equation. In this case, the reconstruction lasts less than 1 min. Stokes based reconstruction of a Navier–Stokes flow in junctions at Reynolds number up to 100 yields the same accuracy and proves fast.
publisherThe American Society of Mechanical Engineers (ASME)
titleInverse Computational Fluid Dynamics: Influence of Discretization and Model Errors on Flows in Water Network Including Junctions
typeJournal Paper
journal volume137
journal issue9
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.4030358
journal fristpage91401
journal lastpage91401
identifier eissn1528-901X
treeJournal of Fluids Engineering:;2015:;volume( 137 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record