Show simple item record

contributor authorGuo, Zheying
contributor authorFreeman, Joseph W.
contributor authorBarrett, Jennifer G.
contributor authorDe Vita, Raffaella
date accessioned2017-05-09T01:15:17Z
date available2017-05-09T01:15:17Z
date issued2015
identifier issn0148-0731
identifier otherbio_137_07_071011.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157151
description abstractIn the past years, there have been several experimental studies that aimed at quantifying the material properties of articular ligaments such as tangent modulus, tensile strength, and ultimate strain. Little has been done to describe their response to mechanical stimuli that lead to damage. The purpose of this experimental study was to characterize straininduced damage in medial collateral ligaments (MCLs). Displacementcontrolled tensile tests were performed on 30 MCLs harvested from Sprague Dawley rats. Each ligament was monotonically pulled to several increasing levels of displacement until complete failure occurred. The stress–strain data collected from the mechanical tests were analyzed to determine the onset of damage and its evolution. Unrecoverable changes such as increase in ligament's elongation at preload and decrease in the tangent modulus of the linear region of the stress–strain curves indicated the occurrence of damage. Interestingly, these changes were found to appear at two significantly different threshold strains (P<0.05). The mean threshold strain that determined the increase in ligament's elongation at preload was found to be 2.84% (standard deviation (SD) = 1.29%) and the mean threshold strain that caused the decrease in the tangent modulus of the linear region was computed to be 5.51% (SD = 2.10%), respectively. The findings of this study suggest that the damage mechanisms associated with the increase in ligament's elongation at preload and decrease in the tangent modulus of the linear region in the stress–strain curves in MCLs are likely different.
publisherThe American Society of Mechanical Engineers (ASME)
titleQuantification of Strain Induced Damage in Medial Collateral Ligaments
typeJournal Paper
journal volume137
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4030532
journal fristpage71011
journal lastpage71011
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record