Show simple item record

contributor authorSheng, Hanlin
contributor authorHuang, Wei
contributor authorZhang, Tianhong
contributor authorHuang, Xianghua
date accessioned2017-05-09T01:07:55Z
date available2017-05-09T01:07:55Z
date issued2014
identifier issn1528-8919
identifier othergtp_136_09_092601.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154799
description abstractA hybrid control system has been proposed for compressor surge, which combines the active method with the passive method. A bleed valve was selected as the actuator in the proposed system. As a submode of the hybrid system, a fuzzy logic based active controller was designed to extend the stability operating range of the compressor. Meanwhile, a surge avoidance controller was used as a backupmode to improve the safety performance of the system. The simulation results showed that the compressor can operate steadily outside the surge line under active control mode and can be dragged back to inside the surge line by the passive control mode when the alternative fails. One advantage of the proposed control system is that it does not need a model of the compressor, and it works on any compression system. Passive surge control is a reliable and widely applied method in industrial compressors. The hybrid system makes the active control approach closer to the industrial implementation.
publisherThe American Society of Mechanical Engineers (ASME)
titleActive/Passive Hybrid Control System for Compressor Surge Based on Fuzzy Logic
typeJournal Paper
journal volume136
journal issue9
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4026953
journal fristpage92601
journal lastpage92601
identifier eissn0742-4795
treeJournal of Engineering for Gas Turbines and Power:;2014:;volume( 136 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record