Show simple item record

contributor authorAndreades, Charalampos
contributor authorDempsey, Lindsay
contributor authorPeterson, Per F.
date accessioned2017-05-09T01:07:45Z
date available2017-05-09T01:07:45Z
date issued2014
identifier issn1528-8919
identifier othergtp_136_07_071703.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154750
description abstractBecause molten fluoride salts can deliver heat at temperatures above 600 آ°C, they can be used to couple nuclear and concentrating solar power heat sources to reheat air combined cycles (RACC). With the openair configuration used in RACC power conversion, the ability to also inject natural gas or other fuel to boost power at times of high demand provides the electric grid with contingency and flexible capacity while also increasing revenues for the operator. This combination provides several distinct benefits over conventional standalone nuclear power plants and natural gas combined cycle and peaking plants. A companion paper discusses the necessary modifications and issues for coupling an external heat source to a conventional gas turbine and provides two baseline designs (derived from the GE 7FB and Alstom GT24). This paper discusses offnominal operation, transient response, and startup and shutdown using the GE 7FB gas turbine as the reference design.
publisherThe American Society of Mechanical Engineers (ASME)
titleReheat Air Brayton Combined Cycle Power Conversion Off Nominal and Transient Performance
typeJournal Paper
journal volume136
journal issue7
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4026612
journal fristpage71703
journal lastpage71703
identifier eissn0742-4795
treeJournal of Engineering for Gas Turbines and Power:;2014:;volume( 136 ):;issue: 007
contenttypeFulltext