description abstractA significant number of elderly patients with severe symptomatic aortic stenosis are denied surgical aortic valve replacement (SAVR) because of high operative risk. Transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to SAVR in these patients. One of the main characteristics of TAVI, when compared to SAVR, is that the diseased native aortic valve remains in place. For hemodynamic testing of new percutaneous valves and clinical training, one should rely on animal models. However, the development of an appropriate animal model of severe aortic stenosis is not straightforward. This work aims at developing and testing an elastic model of the ascending aorta including a severe aortic stenosis. The physical model was built based on a previous silicone model and tested experimentally in this study. Experimental results showed that the error between the computeraided design (CAD) file and the physical elastic model was <5%, the compliance of the ascending aorta was 1.15 ml/mm Hg, the effective orifice area (EOA) of the stenotic valve was 0.86 cm2, the peak jet velocity was 4.9 m/s and mean transvalvular pressure gradient was 50 mm Hg, consistent with as severe. An EDWARDSSAPIEN 26 mm valve was then implanted in the model leading to a significant increase in EOA (2.22 cm2) and a significant decrease in both peak jet velocity (1.29 m/s) and mean transvalvular pressure gradient (3.1 mm Hg). This model can be useful for preliminary in vitro testing of percutaneous valves before more extensive animal and in vivo tests.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn In Vitro Model of Aortic Stenosis for the Assessment of Transcatheter Aortic Valve Implantation
typeJournal Paper
journal volume136
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4026576
journal fristpage54501
journal lastpage54501
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record