description abstractA 10cell hightemperature polymer electrolyte fuel cell (HTPEFC) stack with an active cell area of 200 cm2 has been built up and tested with regard to the temperature distribution from cell to cell and over the active area since not every cell is cooled. Measurements with artificial reformate as a fuel show that the vertical temperature distribution over the active area is sufficiently small, with a maximum of 5.1 K at 550 mA cm−2. Additionally, the temperature gradient from cell to cell is sufficiently small with 10.7 K at 550 mA cm−2. As a result, it can be concluded that the heat pipe supported external cooling is well suited to cool HTPEFC stacks with large active areas in reformate operation.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign and Experimental Investigation of a Heat Pipe Supported External Cooling System for HT PEFC Stacks
typeJournal Paper
journal volume10
journal issue5
journal titleJournal of Fuel Cell Science and Technology
identifier doi10.1115/1.4025052
journal fristpage51002
journal lastpage51002
identifier eissn2381-6910
treeJournal of Fuel Cell Science and Technology:;2013:;volume( 010 ):;issue: 005