Show simple item record

contributor authorThampan, Tony M.
contributor authorGovoni, Mark A.
contributor authorClark, John T.
date accessioned2017-05-09T00:59:26Z
date available2017-05-09T00:59:26Z
date issued2013
identifier issn2381-6872
identifier otherfc_010_04_044501.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151995
description abstractThe increasing use of unattended sensors by the Information, Surveillance, and Reconnaissance community requires the development of higher power and energy density sources to provide increased capabilities and operation time while minimizing size and weight. Among the emerging power sources, fuel cell (FC) systems potentially offer an improved alternative to existing solutions. The Communications and Electronics Research and Development and Engineering Center/Command, Power & Integration Directorate/Army Power Division's Power Sources branch has been evaluating fuel cells to meet tactical power military applications. Testing of methanol based FC systems indicates 50% weight savings over a secondary Liion rechargeable system at 200 W h, and 30% weight savings over a primary Li battery at 600 W h. However, significant technical barriers to fuel cell based power sources for sensor deployment exist, including requirements for additional size and weight reduction to meet portable sensor design requirements. Additionally, testing of FC systems demonstrate the importance of appropriate battery hybridization to maintain load following as well as increasing system power density. A comparison of a Reformed Methanol FC system and a Direct Methanol FC system was also completed, and results for the system size, weight, and fuel consumption are similar for both technologies. To examine the benefits of larger power fuel cells appropriate for stationary unattended sensor use, a comparison of power and weight available from a solar/battery hybrid system versus a solar/battery/RMFC hybrid system was also completed. Although the solar/battery hybrid system's size and weight are larger than the hybrid system with an FC unit, 14 kg versus 8 kg, respectively, there is significant logistic burden when utilizing a FC system due to its methanol refueling requirement.
publisherThe American Society of Mechanical Engineers (ASME)
titleFuel Cell Systems as Power Sources for Sensor Applications
typeJournal Paper
journal volume10
journal issue4
journal titleJournal of Fuel Cell Science and Technology
identifier doi10.1115/1.4024566
journal fristpage44501
journal lastpage44501
identifier eissn2381-6910
treeJournal of Fuel Cell Science and Technology:;2013:;volume( 010 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record