Show simple item record

contributor authorCrawford, James
contributor authorMichael Birk, A.
date accessioned2017-05-09T00:58:52Z
date available2017-05-09T00:58:52Z
date issued2013
identifier issn0098-2202
identifier otherfe_135_3_031206.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151812
description abstractThe influence of calibration data sorting procedures and the order of polynomial curve fit used to calibrate seven hole pressure probes in subsonic, incompressible flow are discussed. It is shown that the inclusion of fourth order polynomial terms is necessary to properly model the physical response of the probe. It is also shown that the uniformity of probe response error is significantly affected by polynomial extrapolation near sector boundaries, and that the uniformity can be improved by using some calibration points in multiple sectors.
publisherThe American Society of Mechanical Engineers (ASME)
titleImprovements to Common Data Reduction and Calibration Methods for Seven Hole Probes
typeJournal Paper
journal volume135
journal issue3
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.4023649
journal fristpage31206
journal lastpage31206
identifier eissn1528-901X
treeJournal of Fluids Engineering:;2013:;volume( 135 ):;issue: 003
contenttypeFulltext