Thermal Energy Requirements of Air-Conditioning SystemsSource: Journal of Engineering for Gas Turbines and Power:;1971:;volume( 093 ):;issue: 002::page 172Author:M. E. Lackey
DOI: 10.1115/1.3445548Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The thermal energy requirements for air conditioning by compressive and absorption methods were determined for light-water, thermal-breeder, and fast-breeder reactors. The energy required to produce a ton-hour of refrigeration varied from 5100 Btu to 13,100 Btu by absorption and from 5600 to 8800 Btu by compression. The amount of waste heat dissipated to the environment at the reactor site as a consequence of producing a ton-hour of air conditioning ranged from an increase of 21,000 Btu for the electric-motor-driven refrigeration system to a decrease of 6000 Btu for the absorption refrigeration system.
keyword(s): Thermal energy , Air conditioning , Absorption , Refrigeration , Compression , Waste heat , Water AND Engines ,
|
Show full item record
| contributor author | M. E. Lackey | |
| date accessioned | 2017-05-09T00:56:48Z | |
| date available | 2017-05-09T00:56:48Z | |
| date copyright | April, 1971 | |
| date issued | 1971 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26692#172_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/151100 | |
| description abstract | The thermal energy requirements for air conditioning by compressive and absorption methods were determined for light-water, thermal-breeder, and fast-breeder reactors. The energy required to produce a ton-hour of refrigeration varied from 5100 Btu to 13,100 Btu by absorption and from 5600 to 8800 Btu by compression. The amount of waste heat dissipated to the environment at the reactor site as a consequence of producing a ton-hour of air conditioning ranged from an increase of 21,000 Btu for the electric-motor-driven refrigeration system to a decrease of 6000 Btu for the absorption refrigeration system. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Thermal Energy Requirements of Air-Conditioning Systems | |
| type | Journal Paper | |
| journal volume | 93 | |
| journal issue | 2 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3445548 | |
| journal fristpage | 172 | |
| journal lastpage | 176 | |
| identifier eissn | 0742-4795 | |
| keywords | Thermal energy | |
| keywords | Air conditioning | |
| keywords | Absorption | |
| keywords | Refrigeration | |
| keywords | Compression | |
| keywords | Waste heat | |
| keywords | Water AND Engines | |
| tree | Journal of Engineering for Gas Turbines and Power:;1971:;volume( 093 ):;issue: 002 | |
| contenttype | Fulltext |