description abstractLeaks in general and hydraulic leaks in specific are one of the major failure modes for mobile equipment. In-plant leak rates may range from 1% to 25%, while field leaks may range from 1% to 13% depending on the complexity of the system, assembly process, and parts quality. In this paper, the main potential leak causes are discussed and the performance of different types of fittings is compared, including JIC 37 flare fittings, O-ring boss seal, and O-ring face seal. Several potential improvement actions related to assembly process, torque specifications, and quality of manufactured fittings are proposed to reduce leaks. Among the many benefits leak reduction will result in improved customer safety and satisfaction, assembly down time reduction, cost and warranty reduction, and environmental impact reduction.
publisherThe American Society of Mechanical Engineers (ASME)
titleFailure Mode Analysis of Mobile Equipment Hydraulic Leaks
typeJournal Paper
journal volume134
journal issue3
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.4006342
journal fristpage34502
identifier eissn1528-8978
keywordsTorque
keywordsFailure
keywordsFittings
keywordsLeakage
keywordsManufacturing
keywordsIndustrial plants AND Seals
treeJournal of Pressure Vessel Technology:;2012:;volume( 134 ):;issue: 003