Show simple item record

contributor authorJ. Mergel
contributor authorH. Janßen
contributor authorM. Müller
contributor authorJ. Wilhelm
contributor authorD. Stolten
date accessioned2017-05-09T00:51:39Z
date available2017-05-09T00:51:39Z
date copyrightJune, 2012
date issued2012
identifier issn2381-6872
identifier otherJFCSAU-28954#031011_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149239
description abstractDirect methanol fuel cells (DMFCs) are attractive for various applications, above all, however, as replacements for batteries or accumulators. They may be used in different power classes. A market analysis indicated that the use of a DMFC energy system in the kW class had the best chance of commercial realization if applied in forklift trucks for material handling in large distribution centers or warehouses. An advantage of such energy systems is that there is no need for the relatively time-consuming recharging of the lead-acid batteries, nor is it necessary to have spare batteries available for multishift operation. This calls for DMFC energy systems that are capable of replacing the existing Pb accumulators in terms of space requirements and energy. However, this requires considerable improvements to be made in terms of power and stability over time of DMFC systems and, in comparison to their present status, an increase of overall efficiency. Recent cost analyses for the overall system; for example, show that for the DMFC stack, a durability of at least 5000 h must be achieved with an overall efficiency for the DMFC system of at least 30%, with the constraint that the system can be operated in a water-autonomous manner up to an ambient temperature of 35 °C. As part of a joint R&D project with industrial partners, two systems were constructed and each subjected to long-term testing for 3000 and more than 8000 h, respectively, with realistic load profiles from driving cycles. In this test, the stack from the first system, DMFC V 3.3–1, displayed an aging rate of approximately 52 μV h−1 at a current density of 100 mA cm−2 . This corresponds to a performance degradation of 25% over a period of 3,000 h. The DMFC V 3.3–2 system, a modified and optimized version of the first system, also underwent long-term testing. In this case, the aging rate of the stack was only approximately 9 μV h−1 at a current density of 100 mA cm−2 . The system has thus been operated to date for more than 8000 h under realistic load profiles.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment of Direct Methanol Fuel Cell Systems for Material Handling Applications
typeJournal Paper
journal volume9
journal issue3
journal titleJournal of Fuel Cell Science and Technology
identifier doi10.1115/1.4006490
journal fristpage31011
identifier eissn2381-6910
keywordsDirect methanol fuel cells
keywordsDesign AND Forklifts
treeJournal of Fuel Cell Science and Technology:;2012:;volume( 009 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record