Show simple item record

contributor authorMehmet Mersinligil
contributor authorNicolas Courtiade
contributor authorXavier Ottavy
contributor authorJean-François Brouckaert
date accessioned2017-05-09T00:50:14Z
date available2017-05-09T00:50:14Z
date copyrightJune, 2012
date issued2012
identifier issn1528-8919
identifier otherJETPEZ-27196#061601_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148816
description abstractOver the last decades, fast response aerodynamic probes have been recognized as a robust measurement technique to provide time-resolved flow field data in turbomachinery environments. Still, most of the existing probe designs are restricted to low temperature applications (<120 °C) either because of sensor temperature range limitations or packaging issues. Measurements in turbomachines also require a small probe size often with a very high bandwidth which are conflicting constraints difficult to satisfy simultaneously. This contribution therefore presents the development of a novel miniature (∅ 2.5 mm ) high temperature single sensor total pressure probe, designed for operation up to 250 °C with a very high bandwidth of 250 kHz. The probe main element is a 1.7 mm diameter commercial piezoresistive transducer placed in a Pitot type arrangement with a flush mounted sensor to provide the highest bandwidth. The details of the probe design are presented as well as the probe calibrations in pressure and in temperature. The effects of using a thermal compensation module or a sense resistor to monitor the temperature drift are described in the context of measurement uncertainty. The probes were characterized in terms of aerodynamic characteristics versus flow angle and Mach number. Shock tube tests have shown a dynamic response of the probe with sensor resonance frequencies well over 300 kHz, with a flat frequency range up to 250 kHz. Two probe prototypes were manufactured and first used in the 3½-stage high speed axial compressor CREATE of the LMFA at École Centrale de Lyon in France. The probes were traversed at each interblade row plane up to temperatures of 180 °C and absolute pressure of 3 bars. The probe was able to resolve the high blade passing frequencies (∼16 kHz) and several harmonics including rotor-stator interaction frequencies up to 200 kHz. Besides the average total pressure distributions from the radial traverses, phase-locked averages and random unsteadiness are presented. The probe spatial and temporal resolutions are discussed in the context of those results.
publisherThe American Society of Mechanical Engineers (ASME)
titleA High Temperature High Bandwidth Fast Response Total Pressure Probe for Measurements in a Multistage Axial Compressor
typeJournal Paper
journal volume134
journal issue6
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4006061
journal fristpage61601
identifier eissn0742-4795
keywordsMeasurement
keywordsSensors
keywordsCompressors
keywordsPressure
keywordsCalibration
keywordsProbes
keywordsFlow (Dynamics)
keywordsRotors
keywordsTemperature
keywordsBlades AND Design
treeJournal of Engineering for Gas Turbines and Power:;2012:;volume( 134 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record