Show simple item record

contributor authorR. Antón
contributor authorA. Bengoechea
contributor authorA. Rivas
contributor authorJ. C. Ramos
contributor authorG. S. Larraona
date accessioned2017-05-09T00:49:33Z
date available2017-05-09T00:49:33Z
date copyrightMarch, 2012
date issued2012
identifier issn1528-9044
identifier otherJEPAE4-26323#011004_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148605
description abstractThe performance of axial fans in close proximity to the electromagnetic compatibility (EMC) screens was analyzed by means of an experimental parametric study. The following geometrical parameters were studied: the hub-to-tip ratio, the ratio between fan thickness and fan diameter, the porosity and thickness of the perforated plate, and finally, the distance between the perforated plate and the inlet and the outlet of the fan. Screen porosity was found to be the most important parameter. Fan performance degradation is expressed by means of two correlations: one for the deterioration in the fan pressure at the no-flow point and the other for the flow rate reduction at the free delivery point. Both correlations were formulated as functions of screen porosity and the distance between the fan and the screen. We believe that the correlations can serve as a good guide for correct fan placement in a telecommunications cabinet.
publisherThe American Society of Mechanical Engineers (ASME)
titlePerformance of Axial Fans in Close Proximity to the Electromagnetic Compatibility Screens
typeJournal Paper
journal volume134
journal issue1
journal titleJournal of Electronic Packaging
identifier doi10.1115/1.4005913
journal fristpage11004
identifier eissn1043-7398
keywordsPressure
keywordsFlow (Dynamics)
keywordsFans
keywordsPorosity
keywordsThickness AND Electromagnetic compatibility
treeJournal of Electronic Packaging:;2012:;volume( 134 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record