Show simple item record

contributor authorRobert A. Siston
contributor authorThomas L. Maack
contributor authorMatthew D. Beal
contributor authorAjit M. W. Chaudhari
contributor authorErin E. Hutter
date accessioned2017-05-09T00:48:18Z
date available2017-05-09T00:48:18Z
date copyrightNovember, 2012
date issued2012
identifier issn0148-0731
identifier otherJBENDY-926471#115001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148178
description abstractThe success of total knee arthroplasty depends, in part, on the ability of the surgeon to properly manage the soft tissues surrounding the joint, but an objective definition as to what constitutes acceptable postoperative joint stability does not exist. Such a definition may not exist due to lack of suitable instrumentation, as joint stability is currently assessed by visual inspection while the surgeon manipulates the joint. Having the ability to accurately and precisely measure knee stability at the time of surgery represents a key requirement in the process of objectively defining acceptable joint stability. Therefore, we created a novel sterilizable device to allow surgeons to measure varus-valgus, internal-external, or anterior-posterior stability of the knee during a total knee arthroplasty. The device can be quickly adjusted between 0 deg and 90 deg of knee flexion. The device interfaces with a custom surgical navigation system, which records the resultant rotations or translations of the knee while the surgeon applies known loads to a patient’s limb with a handle instrumented with a load cell. We validated the performance of the device by having volunteers use it to apply loads to a mechanical linkage that simulated a knee joint; we then compared the joint moments calculated by our stability device against those recorded by a load cell in the simulated knee joint. Validation of the device showed low mean errors (less than 0.21 ± 1.38 Nm and 0.98 ± 3.93 N) and low RMS errors (less than 1.5 Nm and 5 N). Preliminary studies from total knee arthroplasties performed on ten cadaveric specimens also demonstrate the utility of our new device. Eventually, the use of this device may help determine how intra-operative knee stability relates to postoperative function and could lead to an objective definition of knee stability and more efficacious surgical techniques.
publisherThe American Society of Mechanical Engineers (ASME)
titleDesign and Cadaveric Validation of a Novel Device to Quantify Knee Stability During Total Knee Arthroplasty
typeJournal Paper
journal volume134
journal issue11
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4007822
journal fristpage115001
identifier eissn1528-8951
keywordsStability
keywordsStress
keywordsKnee
keywordsArthroplasty
keywordsForce
keywordsSurgery
keywordsNavigation
keywordsDesign AND Errors
treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record