description abstractThe present study investigates the heat transfer performance of W-shaped ribs in a rectangular channel with typical geometries and flow conditions for a combustor liner cooling passage. In order to assess the Reynolds number dependence on heat transfer enhancement by the ribs for the combustor cooling passage, experiments were conducted with channel Reynolds number ranging from 40,000 to 550,000. The ribs were located on one side of the channel and the rib height-to-hydraulic diameter ratio (e/Dh) was 0.006–0.014, which simulate the combustor liner cooling configurations. Rib pitch-to-height ratio (P/e) was 10. Rib-roughened copper plates with constant temperature were used to measure the averaged heat transfer coefficients. Measured results show that the heat transfer enhancements of about 3 were obtained over that of a flat plate at high Reynolds numbers for all cases. The slope of heat transfer coefficient becomes constant with increasing Reynolds number because of the laminar-turbulent transition around the ribs, which is considered to occur at Reynolds number based on rib height of about 1000. Pressure loss measurements showed that the friction coefficients are constantly 3–4.5 times higher than those of a flat plate for a fully turbulent flow such as a combustor cooling passage. Pressure loss by ribs seems not to have a significant impact to the overall combustor performance. Numerical calculations were conducted additionally for all test cases. Predicted amount of heat released from the ribs contributes about 40% of the overall heat release even for low ribs. Heat transfer on the rib surface is essential in the evaluation of the rib-roughened cooling passage.
publisherThe American Society of Mechanical Engineers (ASME)
titleHeat Transfer and Pressure Losses of W-Shaped Small Ribs at High Reynolds Numbers for Combustor Liner
typeJournal Paper
journal volume133
journal issue9
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4002878
journal fristpage91901
identifier eissn0742-4795
keywordsFlow (Dynamics)
keywordsHeat transfer
keywordsChannels (Hydraulic engineering)
keywordsReynolds number
keywordsCombustion chambers
keywordsHeat transfer coefficients
keywordsPressure
keywordsCooling AND Friction
treeJournal of Engineering for Gas Turbines and Power:;2011:;volume( 133 ):;issue: 009