Show simple item record

contributor authorJohan K. Westin
contributor authorJayanta S. Kapat
contributor authorLouis C. Chow
date accessioned2017-05-09T00:40:57Z
date available2017-05-09T00:40:57Z
date copyrightMarch, 2010
date issued2010
identifier issn1948-5085
identifier otherJTSEBV-28813#011002_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144848
description abstractCurrent state-of-the-art thermoregulatory models do not simulate body temperature responses with the accuracies that are required for the development of automatic cooling control in liquid cooling garment (LCG) systems. Automatic cooling control would be beneficial in a variety of space, aviation, military, and industrial environments. It would optimize cooling efficiency, aid in making LCGs as portable and practical as possible, alleviate the individual from manual cooling control, and improve thermal comfort and cognitive performance. In this study, we implement an available state-of-the-art thermoregulatory model in a LCG environment and compare the thermal model response with experimental data for a 700 W rectangular type metabolic rate schedule. We modify the blood flow dynamics of the thermoregulatory model and identify a new vasoconstriction signal, i.e., the rate of change of hypothalamus temperature weighted by the hypothalamus error signal, which governs the thermoregulatory response during conditions of simultaneously increasing core and decreasing skin temperatures. With this new vasoconstriction dependency, the thermoregulatory model simulates rectal and mean skin temperature responses with root mean square deviations of 0.10°C and 0.48°C, respectively, which results in 40% and 17% reductions in the mean and peak body heat storage errors, respectively. Although the new model’s mean body heat storage error is within the allowable by an 11% margin, the peak body heat storage error exceeds the allowable by 222%, indicating that further refinements are needed. With additional improvements to the set-point temperatures, the central blood pool formulation, and the LCG boundary condition, it seems possible to achieve the strict accuracy that is needed for the development of automatic cooling control in LCG systems.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Improved Thermoregulatory Model for Automatic Cooling Control Development in Liquid Cooling Garment Systems
typeJournal Paper
journal volume2
journal issue1
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4001482
journal fristpage11002
identifier eissn1948-5093
keywordsHeat
keywordsTemperature
keywordsCooling
keywordsBlood
keywordsErrors
keywordsSkin
keywordsHeat storage
keywordsBlood flow
keywordsBiological tissues AND Boundary-value problems
treeJournal of Thermal Science and Engineering Applications:;2010:;volume( 002 ):;issue: 001