| contributor author | W. F. Z. Lee | |
| contributor author | H. J. Evans | |
| date accessioned | 2017-05-09T00:37:11Z | |
| date available | 2017-05-09T00:37:11Z | |
| date copyright | December, 1970 | |
| date issued | 1970 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-27372#724_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/142923 | |
| description abstract | The need for a simple and inexpensive method for field checking gas turbine meters exists. One such method called the “spin test” is described in this paper. The relationship between the change of “rotor coast time” of the spin test and the change of meter accuracy due to change of mechanical friction is formulated. Experimental results on two different 6-in. gas turbine meters are presented and show good agreement with analytical results. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Field Method of Determining Gas Turbine Meter Performance | |
| type | Journal Paper | |
| journal volume | 92 | |
| journal issue | 4 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3425121 | |
| journal fristpage | 724 | |
| journal lastpage | 731 | |
| identifier eissn | 1528-901X | |
| keywords | Gas turbines | |
| keywords | Particle spin | |
| keywords | Friction | |
| keywords | Rotors AND Shorelines | |
| tree | Journal of Fluids Engineering:;1970:;volume( 092 ):;issue: 004 | |
| contenttype | Fulltext | |