Show simple item record

contributor authorBrian J. South
contributor authorGordon Bosker
contributor authorRichard R. Neptune
contributor authorNicholas P. Fey
date accessioned2017-05-09T00:36:43Z
date available2017-05-09T00:36:43Z
date copyrightJanuary, 2010
date issued2010
identifier issn0148-0731
identifier otherJBENDY-27091#015001_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142678
description abstractProper selection of prosthetic foot-ankle components with appropriate design characteristics is critical for successful amputee rehabilitation. Elastic energy storage and return (ESAR) feet have been developed in an effort to improve amputee gait. However, the clinical efficacy of ESAR feet has been inconsistent, which could be due to inappropriate stiffness levels prescribed for a given amputee. Although a number of studies have analyzed the effect of ESAR feet on gait performance, the relationships between the stiffness characteristics and gait performance are not well understood. A challenge to understanding these relationships is the inability of current manufacturing techniques to easily generate feet with varying stiffness levels. The objective of this study was to develop a rapid prototyping framework using selective laser sintering (SLS) for the creation of prosthetic feet that can be used as a means to quantify the influence of varying foot stiffness on transtibial amputee walking. The framework successfully duplicated the stiffness characteristics of a commercial carbon fiber ESAR foot. The feet were mechanically tested and an experimental case study was performed to verify that the locomotor characteristics of the amputee’s gait were the same when walking with the carbon fiber ESAR and SLS designs. Three-dimensional ground reaction force, kinematic, and kinetic quantities were measured while the subject walked at 1.2 m/s. The SLS foot was able to replicate the mechanical loading response and locomotor patterns of the ESAR foot within ±2 standard deviations. This validated the current framework as a means to fabricate SLS-based ESAR prosthetic feet. Future work will be directed at creating feet with a range of stiffness levels to investigate appropriate prescription criteria.
publisherThe American Society of Mechanical Engineers (ASME)
titleManufacture of Energy Storage and Return Prosthetic Feet Using Selective Laser Sintering
typeJournal Paper
journal volume132
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4000166
journal fristpage15001
identifier eissn1528-8951
keywordsSintering
keywordsCarbon fibers
keywordsLasers
keywordsEnergy storage
keywordsArtificial limbs
keywordsStiffness
keywordsManufacturing
keywordsComputer-aided design
keywordsTesting AND Design
treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record