description abstractPeriacetabular osteolysis is a potentially difficult surgical challenge, which can often drive the choice of reconstruction methods used in revision hip replacement. For smaller defects, impaction of bone grafts may be sufficient, but larger defects can require filler materials that provide structural support in addition to filling a void. This study utilized finite element analysis (FEA) to examine the state of stress in periprosthetic pelvic bone when subjected to a stair-climbing load and in the presence of two simulated defects, to show the effect of implanting a defect repair implant fabricated from Trabecular Metal™ . Even a small medial bone defect showed a local stress elevation of 4× compared with that seen with an acetabular implant supported by intact periacetabular bone. Local bone stress was much greater (8× the baseline level) for a defect case in which the loss of bone superior to the acetabular implant permitted significant migration. FEA results showed that a repair of the small defect with a Trabecular Metal™ restrictor lowered periprosthetic bone stress to a level comparable to that in the case of a primary implant. For the larger defect case, the use of a Trabecular Metal™ augment provides structural stabilization and helps to restore the THR head center. However, stress in the adjacent periprosthetic bone is lower than that observed in the defect-free acetabulum. In the augment case, the load path between the femoral head and the pelvis now passes through the augment as the superior rim of the acetabulum has been replaced. Contact-induced stress in the augment is similar in magnitude to that seen in the superior rim of the baseline case, although the stress pattern in the augment is noticeably different from that in intact bone.
publisherThe American Society of Mechanical Engineers (ASME)
titleRepair of Periprosthetic Pelvis Defects With Porous Metal Implants: A Finite Element Study
typeJournal Paper
journal volume132
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4000853
journal fristpage21006
identifier eissn1528-8951
keywordsMetals
keywordsMaintenance
keywordsProduct quality
keywordsStress
keywordsBone
keywordsFinite element analysis
keywordsSurgery AND Fillers (Materials)
treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record