Show simple item record

contributor authorTae Ho Kim
contributor authorAnthony W. Breedlove
contributor authorLuis San Andrés
date accessioned2017-05-09T00:35:30Z
date available2017-05-09T00:35:30Z
date copyrightOctober, 2009
date issued2009
identifier issn0742-4787
identifier otherJOTRE9-28769#041703_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142024
description abstractOil-free turbomachinery relies on gas bearing supports for reduced power losses and enhanced rotordynamic stability. Gas foil bearings (GFBs) with bump-strip compliant layers can sustain large loads, both static and dynamic, and provide damping to reduce shaft vibrations. The ultimate load capacity of GFBs depends on the material properties and configuration of the underlying bump-strip structures. In high temperature applications, thermal effects, which change the operating clearances and material properties, can considerably affect the performance of the GFB structure. This paper presents experiments conducted to estimate the structural stiffness of a test GFB for increasing shaft temperatures. A 38.17 mm inner diameter GFB is mounted on a nonrotating hollow shaft affixed to a rigid structure. A cartridge heater inserted into the shaft provides a controllable heat source and thermocouples record the temperatures on the shaft and GFB housing. For increasing shaft temperatures (up to 188°C), increasing static loads (0–133 N) are applied to the bearing and its deflection recorded. In the test configuration, thermal expansion of the GFB housing, larger than that of the shaft, nets a significant increase in radial clearance, which produces a significant reduction in the bearing’s structural stiffness. A simple physical model, which assembles the individual bump stiffnesses, predicts well the measured GFB structural stiffness. Single frequency periodic loads (40–200 Hz) are exerted on the test bearing to identify its dynamic structural stiffness and equivalent viscous damping or a dry-friction coefficient. The GFB dynamic stiffness increases by as much as 50% with dynamic load amplitudes increasing from 13 N to 31 N. The stiffness nearly doubles from low to high frequencies, and most importantly, it decreases by a third as the shaft temperature rises to 188°C. In general, the GFB dynamic stiffness is lower than its static magnitude at low excitation frequencies, while it becomes larger with increasing excitation frequency due apparently to a bump slip-stick phenomenon. The GFB viscous damping is inversely proportional to the amplitude of the dynamic load, excitation frequency, and shaft temperature. The GFB dry-friction coefficient decreases with increasing amplitude of the applied load and shaft temperature, and increases with increasing excitation frequency.
publisherThe American Society of Mechanical Engineers (ASME)
titleCharacterization of a Foil Bearing Structure at Increasing Temperatures: Static Load and Dynamic Force Performance
typeJournal Paper
journal volume131
journal issue4
journal titleJournal of Tribology
identifier doi10.1115/1.3195042
journal fristpage41703
identifier eissn1528-8897
keywordsTemperature
keywordsStress
keywordsBearings
keywordsDamping
keywordsStiffness
keywordsDry-friction whip and whirl
keywordsForce AND Strips
treeJournal of Tribology:;2009:;volume( 131 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record