Show simple item record

contributor authorKatsumasa Miyazaki
contributor authorMasanori Numata
contributor authorKoichi Saito
contributor authorMasahito Mochizuki
date accessioned2017-05-09T00:35:09Z
date available2017-05-09T00:35:09Z
date copyrightApril, 2009
date issued2009
identifier issn0094-9930
identifier otherJPVTAS-28506#021205_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141829
description abstractThe fixed conditions of butt welds between straight pipe and the valves or pump in an actual piping system are different from those of straight pipes. However, the effect of the fixed condition on the residual stress and the stress intensity factor for the evaluation of the structural integrity of cracked piping is not clear. In this study, finite element analyses were conducted by considering the differences in the distance from the center of weld to the fixed end L, to clarify the effect of the fixed condition on the residual stress and the stress intensity factor. For 600A piping, the residual stress distribution was not affected by L. Furthermore, the stress intensity factors of circumferential cracks under the residual stress field can be estimated by using an existing simplified solution for piping.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Effect of the Distance From the Center of a Weld to the Fixed End on the Residual Stress and Stress Intensity Factor of a Piping Weld
typeJournal Paper
journal volume131
journal issue2
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.3007428
journal fristpage21205
identifier eissn1528-8978
treeJournal of Pressure Vessel Technology:;2009:;volume( 131 ):;issue: 002