Show simple item record

contributor authorStéphane Gossé
contributor authorThierry Alpettaz
contributor authorSylvie Chatain
contributor authorChristine Guéneau
date accessioned2017-05-09T00:32:30Z
date available2017-05-09T00:32:30Z
date copyrightNovember, 2009
date issued2009
identifier issn1528-8919
identifier otherJETPEZ-27086#062901_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/140395
description abstractThe alloys Haynes 230 and Inconel 617 are potential candidates for the intermediate heat exchangers (IHXs) of (very) high temperature reactors ((V)-HTRs). The behavior under corrosion of these alloys by the (V)-HTR coolant (impure helium) is an important selection criterion because it defines the service life of these components. At high temperature, the Haynes 230 is likely to develop a chromium oxide on the surface. This layer protects from the exchanges with the surrounding medium and thus confers certain passivity on metal. At very high temperature, the initial microstructure made up of austenitic grains and coarse intra- and intergranular M6C carbide grains rich in W will evolve. The M6C carbides remain and some M23C6 richer in Cr appear. Then, carbon can reduce the protective oxide layer. The alloy loses its protective coating and can corrode quickly. Experimental investigations were performed on these nickel based alloys under an impure helium flow (, 2007, “Mécanismes de formation et de destruction de la couche d’oxyde sur un alliage chrominoformeur en milieu HTR,” Ph.D. thesis, Ecole des Mines de Saint-Etienne, France). To predict the surface reactivity of chromium under impure helium, it is necessary to determine its chemical activity in a temperature range close to the operating conditions of the heat exchangers (T≈1273 K). For that, high temperature mass spectrometry measurements coupled to multiple effusion Knudsen cells are carried out on several samples: Haynes 230, Inconel 617, and model alloys 1178, 1181, and 1201. This coupling makes it possible for the thermodynamic equilibrium to be obtained between the vapor phase and the condensed phase of the sample. The measurement of the chromium ionic intensity (I) of the molecular beam resulting from a cell containing an alloy provides the values of partial pressure according to the temperature. This value is compared with that of the pure substance (Cr) at the same temperature. These calculations provide thermodynamic data characteristic of the chromium behavior in these alloys. These activity results call into question those previously measured by Hilpert and Ali-Khan (1978, “Mass Spectrometric Studies of Alloys Proposed for High-Temperature Reactor Systems: I. Alloy IN-643,” J. Nucl. Mater., 78, pp. 265–271; 1979, “Mass Spectrometric Studies of Alloys Proposed for High-Temperature Reactor Systems: II. Inconel Alloy 617 and Nimomic Alloy PE 13,” J. Nucl. Mater., 80, pp. 126–131), largely used in the literature.
publisherThe American Society of Mechanical Engineers (ASME)
titleChromium Activity Measurements in Nickel Based Alloys for Very High Temperature Reactors: Inconel 617, Haynes 230, and Model Alloys
typeJournal Paper
journal volume131
journal issue6
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3094017
journal fristpage62901
identifier eissn0742-4795
keywordsTemperature
keywordsNickel
keywordsAlloys
keywordsMeasurement AND High temperature
treeJournal of Engineering for Gas Turbines and Power:;2009:;volume( 131 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record