Show simple item record

contributor authorStephen P. Lownie
contributor authorEdwin M. DeMont
contributor authorWojciech Kalata
contributor authorMatthew D. Ford
contributor authorHristo N. Nikolov
contributor authorDavid W. Holdsworth
contributor authorDavid A. Steinman
contributor authorJaques S. Milner
contributor authorFrancis Loth
date accessioned2017-05-09T00:27:03Z
date available2017-05-09T00:27:03Z
date copyrightApril, 2008
date issued2008
identifier issn0148-0731
identifier otherJBENDY-26799#021015_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137490
description abstractComputational fluid dynamics (CFD) modeling of nominally patient-specific cerebral aneurysms is increasingly being used as a research tool to further understand the development, prognosis, and treatment of brain aneurysms. We have previously developed virtual angiography to indirectly validate CFD-predicted gross flow dynamics against the routinely acquired digital subtraction angiograms. Toward a more direct validation, here we compare detailed, CFD-predicted velocity fields against those measured using particle imaging velocimetry (PIV). Two anatomically realistic flow-through phantoms, one a giant internal carotid artery (ICA) aneurysm and the other a basilar artery (BA) tip aneurysm, were constructed of a clear silicone elastomer. The phantoms were placed within a computer-controlled flow loop, programed with representative flow rate waveforms. PIV images were collected on several anterior-posterior (AP) and lateral (LAT) planes. CFD simulations were then carried out using a well-validated, in-house solver, based on micro-CT reconstructions of the geometries of the flow-through phantoms and inlet/outlet boundary conditions derived from flow rates measured during the PIV experiments. PIV and CFD results from the central AP plane of the ICA aneurysm showed a large stable vortex throughout the cardiac cycle. Complex vortex dynamics, captured by PIV and CFD, persisted throughout the cardiac cycle on the central LAT plane. Velocity vector fields showed good overall agreement. For the BA, aneurysm agreement was more compelling, with both PIV and CFD similarly resolving the dynamics of counter-rotating vortices on both AP and LAT planes. Despite the imposition of periodic flow boundary conditions for the CFD simulations, cycle-to-cycle fluctuations were evident in the BA aneurysm simulations, which agreed well, in terms of both amplitudes and spatial distributions, with cycle-to-cycle fluctuations measured by PIV in the same geometry. The overall good agreement between PIV and CFD suggests that CFD can reliably predict the details of the intra-aneurysmal flow dynamics observed in anatomically realistic in vitro models. Nevertheless, given the various modeling assumptions, this does not prove that they are mimicking the actual in vivo hemodynamics, and so validations against in vivo data are encouraged whenever possible.
publisherThe American Society of Mechanical Engineers (ASME)
titlePIV-Measured Versus CFD-Predicted Flow Dynamics in Anatomically Realistic Cerebral Aneurysm Models
typeJournal Paper
journal volume130
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2900724
journal fristpage21015
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsComputational fluid dynamics
keywordsPhantoms
keywordsAneurysms
keywordsCycles
keywordsEngineering simulation AND Particulate matter
treeJournal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record