Show simple item record

contributor authorYoungbae Park
contributor authorHoChul Shin
contributor authorDonOk Choi
contributor authorCarolyne Albert
contributor authorYong-San Yoon
date accessioned2017-05-09T00:27:02Z
date available2017-05-09T00:27:02Z
date copyrightApril, 2008
date issued2008
identifier issn0148-0731
identifier otherJBENDY-26799#021008_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137482
description abstractLarge interfacial gaps between the stem and the bone in cementless total hip arthroplasty may prevent successful bone ingrowth at the sites, and can also be a passage for wear particles. Furthermore, interfacial gaps between the stem and the bone are believed to compromise the primary stability of the implant. Thus, a broaching method that serves to reduce gaps is expected to give clinically preferable results. A modified broach system with a canal guide is introduced to enhance the accuracy of femoral canal shaping in comparison with the conventional broach system for a Versys™ fibermetal taper stem. The primary stability of the hip systems and the ratios of the stem surface in contact with the femur were measured in a composite femur model. With the conventional method, an average of 67% of the stem surface was shown to be in contact with the bone, and an average stem micromotion/migration of 35μm∕290μm was observed under 1000cycles of stair climbing loads. With the modified method, the stem-bone contact ratio significantly increased to 82% (p<0.05), and the average micromotion/migration reduced to 29μm∕49μm, respectively (p<0.05 for migration). Our finite element models of the hip systems supported that the difference in micromotion could be attributed to the difference in interfacial contact. Interfacial gaps occurring with the conventional broach system were effectively reduced by the proposed method, resulting in improved primary stability.
publisherThe American Society of Mechanical Engineers (ASME)
titlePrimary Stability of Cementless Stem in THA Improved With Reduced Interfacial Gaps
typeJournal Paper
journal volume130
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2898761
journal fristpage21008
identifier eissn1528-8951
keywordsStability
keywordsCanals
keywordsBone
keywordsFinite element model
keywordsStairs
keywordsStress
keywordsComposite materials
keywordsCycles AND Motion
treeJournal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record