| description abstract | In recent years a diamond-like carbon (DLC) film and a 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer have attracted attention as coating materials for implantable artificial organs or devices. When these materials are coated on vascular devices, compatibility to blood is an important problem. The present paper focuses on friction characteristics of erythrocytes to these coating materials in a medium. With an inclined centrifuge microscope developed by the authors, observation was made for erythrocytes moving on flat glass plates with and without coating in a medium of plasma or saline under the effect of inclined centrifugal force. Friction characteristics of erythrocytes with respect to these coating materials were then measured and compared to each other to characterize DLC and MPC as coating materials. The friction characteristics of erythrocytes in plasma using the DLC-coated and noncoated glass plates are similar, changing approximately proportional to the 0.5th power of the cell velocity. The cells stick to these plates in saline as well, implying the influence of plasma protein. The results using the MPC-coated plate in plasma are similar to those of the other plates for large cell velocities, but deviate from the other results with decreased cell velocity. The results change nearly proportional to the 0.75th power of the cell velocity in the range of small velocities. The results for the MPC-coated plate in saline are similar to that in plasma but somewhat smaller, implying that the friction characteristics for the MPC-coated plate are essentially independent of plasma protein. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Frictional Characteristics of Erythrocytes on Coated Glass Plates Subject to Inclined Centrifugal Forces | |
| type | Journal Paper | |
| journal volume | 130 | |
| journal issue | 5 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.2948420 | |
| journal fristpage | 51007 | |
| identifier eissn | 1528-8951 | |
| keywords | Force | |
| keywords | Friction | |
| keywords | Glass | |
| keywords | Centrifugal force | |
| keywords | Plasmas (Ionized gases) | |
| keywords | Plates (structures) | |
| keywords | Microscopes | |
| keywords | Erythrocytes | |
| keywords | Blood AND Polymers | |
| tree | Journal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 005 | |
| contenttype | Fulltext | |