Show simple item record

contributor authorMark van Roode
contributor authorJeff Price
contributor authorJosh Kimmel
contributor authorNaren Miriyala
contributor authorDon Leroux
contributor authorAnthony Fahme
contributor authorKenneth Smith
date accessioned2017-05-09T00:23:47Z
date available2017-05-09T00:23:47Z
date copyrightJanuary, 2007
date issued2007
identifier issn1528-8919
identifier otherJETPEZ-26935#21_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135766
description abstractSolar Turbines Incorporated, under U.S. government sponsored programs, has been evaluating ceramic matrix composite combustor liners in test rigs and Solar’s Centaur® 50S gas turbine engines since 1992. The objective is to evaluate and improve the performance and durability of CMCs as high-temperature materials for advanced low emissions combustors. Field testing of CMC combustor liners started in May of 1997 and by the end of 2004, over 67,000 operating hours had been accumulated on SiC∕SiC and oxide∕oxide CMC liners. NOx and CO emissions have been consistently <15ppmv and <10ppmv, respectively. Maximum test durations of 15,144h and 13,937h have been logged for SiC∕SiC liners with protective environmental barrier coatings. An oxide∕oxide CMC liner with a Friable Graded Insulation coating has been tested for 12,582h. EBCs significantly improve SiC∕SiC CMC liner life. The basic three-layer EBC consists of consecutive layers of Si, mullite, and BSAS. The durability of the baseline EBC can be improved by mixing BSAS with mullite in the intermediate coating layer. The efficacy of replacing BSAS with SAS has not been demonstrated yet. Heavy degradation was observed for two-layer Si∕BSAS and Si∕SAS EBCs, indicating that the elimination of the intermediate layer is detrimental to EBC durability. Equivalent performance was observed when the Hi-Nicalon fiber reinforcement was replaced with Tyranno ZM or ZMI fiber. Melt infiltrated SiC∕SiC CMCs have improved durability compared to SiC∕SiC CMCs fabricated by Chemical Vapor Infiltration of the matrix, in the absence of an EBC. However, the presence of an EBC results in roughly equivalent service life for MI and CVI CMCs. Results to date indicate that oxide∕oxide CMCs with protective FGI show minor degradation under Centaur® 50S gas turbine engine operating conditions. The results of, and lessons learned from CMC combustor liner engine field testing, conducted through 2004, have been summarized.
publisherThe American Society of Mechanical Engineers (ASME)
titleCeramic Matrix Composite Combustor Liners: A Summary of Field Evaluations
typeJournal Paper
journal volume129
journal issue1
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.2181182
journal fristpage21
journal lastpage30
identifier eissn0742-4795
keywordsEngines
keywordsCeramic matrix composites
keywordsCombustion chambers AND Testing
treeJournal of Engineering for Gas Turbines and Power:;2007:;volume( 129 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)