Show simple item record

contributor authorS. R. Jernigan
contributor authorD. R. Cormier
contributor authorG. D. Buckner
contributor authorJ. W. Eischen
date accessioned2017-05-09T00:22:39Z
date available2017-05-09T00:22:39Z
date copyrightDecember, 2007
date issued2007
identifier issn0148-0731
identifier otherJBENDY-26773#825_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135188
description abstractWith the worldwide prevalence of cardiovascular diseases, much attention has been focused on simulating the characteristics of the human heart to better understand and treat cardiac disorders. The purpose of this study is to build a finite element model of the left atrium (LA) that incorporates detailed anatomical features and realistic material characteristics to investigate the interaction of heart tissue and surgical instruments. This model is used to facilitate the design of an endoscopically deployable atrial retractor for use in minimally invasive, robotically assisted mitral valve repair. Magnetic resonance imaging (MRI) scans of a pressurized explanted porcine heart were taken to provide a 3D solid model of the heart geometry, while uniaxial tensile tests of porcine left atrial tissue were conducted to obtain realistic material properties for noncontractile cardiac tissue. A finite element model of the LA was constructed using ANSYS ™ Release 9.0 software and the MRI data. The Mooney–Rivlin hyperelastic material model was chosen to characterize the passive left atrial tissue; material constants were derived from tensile test data. Finite element analysis (FEA) models of a CardioVations Port Access™ retractor and a prototype endoscopic retractor were constructed to simulate interaction between each instrument and the LA. These contact simulations were used to compare the quality of retraction between the two instruments and to optimize the design of the prototype retractor. Model accuracy was verified by comparing simulated cardiac wall deflections to those measured by MRI. FEA simulations revealed that peak forces of approximately 2.85N and 2.46N were required to retract the LA using the Port Access™ and prototype retractors, respectively. These forces varied nonlinearly with retractor blade displacement. Dilation of the atrial walls and rigid body motion of the chamber were approximately the same for both retractors. Finite element analysis is shown to be an effective tool for analyzing instrument/tissue interactions and for designing surgical instruments. The benefits of this approach to medical device design are significant when compared to the alternatives: constructing prototypes and evaluating them via animal or clinical trials.
publisherThe American Society of Mechanical Engineers (ASME)
titleFinite Element Modeling of the Left Atrium to Facilitate the Design of an Endoscopic Atrial Retractor
typeJournal Paper
journal volume129
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2801650
journal fristpage825
journal lastpage837
identifier eissn1528-8951
keywordsSolid models
keywordsEngineering prototypes
keywordsMaterials properties
keywordsBiological tissues
keywordsDesign
keywordsEndoscopic devices
keywordsFinite element analysis
keywordsMagnetic resonance imaging
keywordsBlades
keywordsGeometry
keywordsModeling
keywordsConstruction
keywordsWire
keywordsForce
keywordsComputer software AND Finite element model
treeJournal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record