Show simple item record

contributor authorHiraku Sakamoto
contributor authorK. C. Park
date accessioned2017-05-09T00:22:04Z
date available2017-05-09T00:22:04Z
date copyrightDecember, 2006
date issued2006
identifier issn1048-9002
identifier otherJVACEK-28883#790_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134902
description abstractThe present study explores both structural and controller design to attenuate vibration in large membrane space structures, especially due to low-frequency harmonic excitations. It is very difficult for membrane structures to suppress the low-frequency vibration induced by flexible support structures, because a lightly prestressed membrane has extremely low mode frequencies and little damping effect. The present study proposes the use of weblike perimeter cables around a membrane, and the application of simple and lightweight active controllers only along the web cables in order to isolate the membrane from vibration. This strategy successfully reduces the membrane vibration when the web-cable configuration is appropriately tailored. Both linear and nonlinear finite-element analyses exhibit a clear tradeoff between structural mass and control efficiency.
publisherThe American Society of Mechanical Engineers (ASME)
titleLocalized Vibration Isolation Strategy for Low-Frequency Excitations in Membrane Space Structures
typeJournal Paper
journal volume128
journal issue6
journal titleJournal of Vibration and Acoustics
identifier doi10.1115/1.2203341
journal fristpage790
journal lastpage797
identifier eissn1528-8927
keywordsControl equipment
keywordsCables
keywordsDesign
keywordsMembranes
keywordsVibration AND Space frame structures
treeJournal of Vibration and Acoustics:;2006:;volume( 128 ):;issue: 006