Show simple item record

contributor authorG. Dugan Johnson
date accessioned2017-05-09T00:21:10Z
date available2017-05-09T00:21:10Z
date copyrightSeptember, 1969
date issued1969
identifier issn0098-2202
identifier otherJFEGA4-27339#434_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134390
description abstractThe author demonstrates that significant basic errors are introduced into the Gibson method of measuring water flow rates, even in uniform straight pipes, by failure to take account of velocity distribution in calculating results. Dr. Thoma’s 1926 analysis of the method is quoted extensively, including his conclusion that long straight lengths of pipe upstream and downstream from straight differential-diagram test sections would eliminate the effects of accessory motions and his recommendations for establishing an experimental installation to determine the effects of various disturbed flow conditions. The need for these correction factors or “meter coefficients” in order to avoid consistent errors of approximately 2 percent is emphasized.
publisherThe American Society of Mechanical Engineers (ASME)
titleVelocity Distribution and Its Effect on the Accuracy of the Gibson Method of Water Measurement
typeJournal Paper
journal volume91
journal issue3
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3571144
journal fristpage434
journal lastpage438
identifier eissn1528-901X
keywordsWater
keywordsFlow (Dynamics)
keywordsPipes
keywordsErrors
keywordsFailure AND Motion
treeJournal of Fluids Engineering:;1969:;volume( 091 ):;issue: 003
contenttypeFulltext