Show simple item record

contributor authorA. Ramos
contributor authorF. Fonseca
contributor authorJ. A. Simões
date accessioned2017-05-09T00:18:55Z
date available2017-05-09T00:18:55Z
date copyrightAugust, 2006
date issued2006
identifier issn0148-0731
identifier otherJBENDY-26601#579_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133181
description abstractThe determination of biomechanical force systems of implanted femurs to obtain adequate strain measurements has been neglected in many published studies. Due to geometric alterations induced by surgery and those inherent to the design of the prosthesis, the loading system changes because the lever arms are modified. This paper discusses the determination of adequate loading of the implanted femur based on the intact femur-loading configuration. Four reconstructions with Lubinus SPII, Charnley Roundback, Müller Straight and Stanmore prostheses were used in the study. Pseudophysiologic and nonphysiologic implanted system forces were generated and assessed with finite element analysis. Using an equilibrium system of forces composed by the Fx (medially direction) component of the hip contact force and the bending moments Mx (median plane) and My (coronal plane) allowed adequate, pseudo-physiological loading of the implanted femur. We suggest that at least the bending moment at the coronal plane must be restored in the implanted femur-loading configuration.
publisherThe American Society of Mechanical Engineers (ASME)
titleSimulation of Physiological Loading in Total Hip Replacements
typeJournal Paper
journal volume128
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2205864
journal fristpage579
journal lastpage587
identifier eissn1528-8951
keywordsForce
keywordsStress
keywordsProstheses
keywordsPhysiology
keywordsHip joint prostheses
keywordsFinite element analysis
keywordsSimulation
keywordsEquilibrium (Physics)
keywordsLevers
keywordsBiomechanics
keywordsDesign AND Strain measurement
treeJournal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record