Show simple item record

contributor authorYiemeng Hoi
contributor authorDale B. Taulbee
contributor authorHui Meng
contributor authorScott H. Woodward
contributor authorMinsuok Kim
date accessioned2017-05-09T00:18:46Z
date available2017-05-09T00:18:46Z
date copyrightDecember, 2006
date issued2006
identifier issn0148-0731
identifier otherJBENDY-26642#844_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133126
description abstractBackground. Computational fluid dynamics (CFD) simulations using medical-image-based anatomical vascular geometry are now gaining clinical relevance. This study aimed at validating the CFD methodology for studying cerebral aneurysms by using particle image velocimetry (PIV) measurements, with a focus on the effects of small geometric variations in aneurysm models on the flow dynamics obtained with CFD. Method of Approach. An experimental phantom was fabricated out of silicone elastomer to best mimic a spherical aneurysm model. PIV measurements were obtained from the phantom and compared with the CFD results from an ideal spherical aneurysm model (S1). These measurements were also compared with CFD results, based on the geometry reconstructed from three-dimensional images of the experimental phantom. We further performed CFD analysis on two geometric variations, S2 and S3, of the phantom to investigate the effects of small geometric variations on the aneurysmal flow field. Results. We found poor agreement between the CFD results from the ideal spherical aneurysm model and the PIV measurements from the phantom, including inconsistent secondary flow patterns. The CFD results based on the actual phantom geometry, however, matched well with the PIV measurements. CFD of models S2 and S3 produced qualitatively similar flow fields to that of the phantom but quantitatively significant changes in key hemodynamic parameters such as vorticity, positive circulation, and wall shear stress. Conclusion. CFD simulation results can closely match experimental measurements as long as both are performed on the same model geometry. Small geometric variations on the aneurysm model can significantly alter the flow-field and key hemodynamic parameters. Since medical images are subjected to geometric uncertainties, image-based patient-specific CFD results must be carefully scrutinized before providing clinical feedback.
publisherThe American Society of Mechanical Engineers (ASME)
titleValidation of CFD Simulations of Cerebral Aneurysms With Implication of Geometric Variations
typeJournal Paper
journal volume128
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2354209
journal fristpage844
journal lastpage851
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsComputational fluid dynamics
keywordsPhantoms
keywordsAneurysms AND Geometry
treeJournal of Biomechanical Engineering:;2006:;volume( 128 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record