Show simple item record

contributor authorW. Wilson
contributor authorC. C. van Donkelaar
contributor authorJ. M. Huyghe
date accessioned2017-05-09T00:15:27Z
date available2017-05-09T00:15:27Z
date copyrightFebruary, 2005
date issued2005
identifier issn0148-0731
identifier otherJBENDY-26445#158_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131442
description abstractBiological tissues like intervertebral discs and articular cartilage primarily consist of interstitial fluid, collagen fibrils and negatively charged proteoglycans. Due to the fixed charges of the proteoglycans, the total ion concentration inside the tissue is higher than in the surrounding synovial fluid (cation concentration is higher and the anion concentration is lower). This excess of ion particles leads to an osmotic pressure difference, which causes swelling of the tissue. In the last decade several mechano-electrochemical models, which include this mechanism, have been developed. As these models are complex and computationally expensive, it is only possible to analyze geometrically relatively small problems. Furthermore, there is still no commercial finite element tool that includes such a mechano-electrochemical theory. Lanir (Biorheology, 24 , pp. 173–187, 1987) hypothesized that electrolyte flux in articular cartilage can be neglected in mechanical studies. Lanir’s hypothesis implies that the swelling behavior of cartilage is only determined by deformation of the solid and by fluid flow. Hence, the response could be described by adding a deformation-dependent pressure term to the standard biphasic equations. Based on this theory we developed a biphasic swelling model. The goal of the study was to test Lanir’s hypothesis for a range of material properties. We compared the deformation behavior predicted by the biphasic swelling model and a full mechano-electrochemical model for confined compression and 1D swelling. It was shown that, depending on the material properties, the biphasic swelling model behaves largely the same as the mechano-electrochemical model, with regard to stresses and strains in the tissue following either mechanical or chemical perturbations. Hence, the biphasic swelling model could be an alternative for the more complex mechano-electrochemical model, in those cases where the ion flux itself is not the subject of the study. We propose thumbrules to estimate the correlation between the two models for specific problems.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Comparison Between Mechano-Electrochemical and Biphasic Swelling Theories for Soft Hydrated Tissues
typeJournal Paper
journal volume127
journal issue1
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.1835361
journal fristpage158
journal lastpage165
identifier eissn1528-8951
keywordsPressure
keywordsDeformation
keywordsPermeability
keywordsBiological tissues
keywordsCompression
keywordsEquations
keywordsMaterials properties
keywordsCartilage
keywordsStress
keywordsFluids
keywordsFluid dynamics
keywordsFinite element analysis AND Circuits
treeJournal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record