Show simple item record

contributor authorThomas O'Brien
contributor authorLiam Morris
contributor authorMichael Walsh
contributor authorTim McGloughlin
date accessioned2017-05-09T00:15:15Z
date available2017-05-09T00:15:15Z
date copyrightOctober, 2005
date issued2005
identifier issn0148-0731
identifier otherJBENDY-26537#881_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131330
description abstractThe long term patency of end-to-side peripheral artery bypasses are low due to failure of the graft generally at the distal end of the bypass. Both material mismatch between the graft and the host artery and junction hemodynamics are cited as being major factors in disease formation at the junction. This study uses experimental methods to investigate the major differences in fluid dynamics and wall mechanics at the proximal and distal ends for rigid and compliant bypass grafts. Injection moulding was used to produce idealized transparent and compliant models of the graft/artery junction configuration. An ePTFE graft was then used to stiffen one of the models. These models were then investigated using two-dimensional video extensometry and one-dimensional laser Doppler anemometry to determine the junction deformations and fluid velocity profiles for the rigid and complaint graft anastomotic junctions. Junction strains were evaluated and generally found to be under 5% with a peak stain measured in the stiff graft model junction of 8.3% at 100mmHg applied pressure. Hemodynamic results were found to yield up to 40% difference in fluid velocities for the stiff/compliant comparison but up to 80% for the proximal/distal end comparisons. Similar strain conditions were assumed for the proximal and distal models while significant differences were noted in their associated hemodynamic changes. In contrasting the fluid dynamics and wall mechanics for the proximal and distal anastomoses, it is evident from the results of this study, that junction hemodynamics are the more variable factor.
publisherThe American Society of Mechanical Engineers (ASME)
titleThat Hemodynamics and Not Material Mismatch is of Primary Concern in Bypass Graft Failure: An Experimental Argument
typeJournal Paper
journal volume127
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.1992532
journal fristpage881
journal lastpage886
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsDeformation
keywordsFailure
keywordsHemodynamics
keywordsJunctions
keywordsPressure
keywordsDiseases
keywordsLaser Doppler anemometry AND Fluids
treeJournal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 005
contenttypeFulltext