Show simple item record

contributor authorMichael G. Izenson
contributor authorRoger W. Hill
date accessioned2017-05-09T00:13:31Z
date available2017-05-09T00:13:31Z
date copyrightNovember, 2004
date issued2004
identifier issn2381-6872
identifier otherJFCSAU-27238#10_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/130305
description abstractA key consideration for portable power systems is that they must operate simultaneously at water balance (no external water supply) and thermal balance (controlled temperature). Water and thermal management are intimately linked since evaporation is a potent source of cooling. This paper presents the basic design relationships that govern water and thermal balance in polymer electrolyte membrane (PEM) fuel cell stacks and systems. Hydrogen/air and direct methanol fuel cells are both addressed and compared. Operating conditions for simultaneous water and thermal balance can be specified based on the cell’s electrochemical performance and the operating environment. These conditions can be used to specify the overall size and complexity of the cooling equipment. The water balance properties can have strong effects on the size of the thermal management equipment required.
publisherThe American Society of Mechanical Engineers (ASME)
titleWater and Thermal Balance in PEM and Direct Methanol Fuel Cells
typeJournal Paper
journal volume1
journal issue1
journal titleJournal of Fuel Cell Science and Technology
identifier doi10.1115/1.1782918
journal fristpage10
journal lastpage17
identifier eissn2381-6910
keywordsHeat
keywordsTemperature
keywordsCooling
keywordsFuel cells
keywordsHeat exchangers
keywordsDirect methanol fuel cells
keywordsWater AND Condensers (steam plant)
treeJournal of Fuel Cell Science and Technology:;2004:;volume( 001 ):;issue: 001