Show simple item record

contributor authorLoay Massalha
contributor authorAvraham Shitzer
date accessioned2017-05-09T00:12:15Z
date available2017-05-09T00:12:15Z
date copyrightDecember, 2004
date issued2004
identifier issn0148-0731
identifier otherJBENDY-26409#736_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/129552
description abstractThe effects of a thermally-significant blood vessel, simulated by an embedded acrylic tube, 4.8 mm outer diameter, on the freezing field caused by a surface cryoprobe were studied experimentally in a tissue phantom. The flat, 15 mm diameter, circular cryoprobe was operated at a constant cooling rate of −8°C/min by liquid nitrogen down to −160°C. Water flow rates of 30 and 100 ml/min, at a constant temperature of 32.5°C, were maintained in the embedded tube. The latter flow rate is typical to the lower range of blood flows in large arteries in the human body. The phase changing medium (PCM) used was a 30/70% by volume mashed potatoes flakes–water solution. Temperature measurements inside the PCM were performed in one plane perpendicular to the embedded tube, relative to which the cryoprobe was placed at 5 locations in separate experiments. This novel experimental method reduced the perturbation caused by the thermocouple junctions while facilitating rather detailed measurements of the temperature fields developing in the PCM. Results show the development of two hump-like formations on either side of the embedded tube. Freezing was retarded in the region away from the surface cryoprobe and under the tube. This accentuated the dominance of the axial effects, due to the embedded tube, over the radial ones due to the cryoprobe. Results of this study should be considered in designing protocols of cryosurgical procedures performed in the vicinity of thermally-significant blood vessels.
publisherThe American Society of Mechanical Engineers (ASME)
titleFreezing by a Flat, Circular Surface Cryoprobe of a Tissue Phantom With an Embedded Cylindrical Heat Source Simulating a Blood Vessel
typeJournal Paper
journal volume126
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.1824119
journal fristpage736
journal lastpage744
identifier eissn1528-8951
keywordsFlow (Dynamics)
keywordsHeat
keywordsTemperature
keywordsFreezing
keywordsBiological tissues
keywordsBlood vessels
keywordsPhantoms
keywordsWater
keywordsThermocouples
keywordsJunctions AND Cooling
treeJournal of Biomechanical Engineering:;2004:;volume( 126 ):;issue: 006
contenttypeFulltext