Show simple item record

contributor authorSrinivas Garimella
contributor authorJesse D. Killion
contributor authorJohn W. Coleman
date accessioned2017-05-09T00:10:30Z
date available2017-05-09T00:10:30Z
date copyrightSeptember, 2003
date issued2003
identifier issn0098-2202
identifier otherJFEGA4-27190#887_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/128561
description abstractThis paper reports the development of an experimentally validated model for pressure drop during intermittent flow of condensing refrigerant R134a in horizontal, noncircular microchannels. Two-phase pressure drops were measured in six noncircular channels ranging in hydraulic diameter from 0.42 mm to 0.84 mm. The tube shapes included square, rectangular, triangular, barrel-shaped, and others. For each tube under consideration, pressure drop measurements were taken over the entire range of qualities from vapor to liquid at five different refrigerant mass fluxes between 150 kg/m2 s and 750 kg/m2 s. Results from previous work by the authors were used to select the data that correspond to the intermittent flow regime; generally, these points had qualities less than 25%. The pressure drop model previously developed by the authors for circular microchannels was used as the basis for the model presented in this paper. Using the observed slug/bubble flow pattern for these conditions, the model includes the contributions of the liquid slug, the vapor bubble, and the transitions between the bubble and slugs. A simple correlation for nondimensional unit-cell length was used to estimate the slug frequency. The model successfully predicts the experimentally measured pressure drops for the noncircular tube shapes under consideration with 90% of the predictions within ±28% of the measurements (average error 16.5%), which is shown to be much better than the predictions of other models in the literature. The effects of tube shape on condensation pressure drop are also illustrated in the paper.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Expermentally Validated Model for Two-Phase Pressure Drop in the Intermittent Flow Regime for Noncircular Microchannels
typeJournal Paper
journal volume125
journal issue5
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.1601258
journal fristpage887
journal lastpage894
identifier eissn1528-901X
keywordsFlow (Dynamics)
keywordsBubbles
keywordsPressure drop
keywordsShapes
keywordsSlug
keywordsMicrochannels
keywordsVapors
keywordsRefrigerants AND Condensation
treeJournal of Fluids Engineering:;2003:;volume( 125 ):;issue: 005