Show simple item record

contributor authorS. Garimella
contributor authorJ. D. Killion
contributor authorJ. W. Coleman
date accessioned2017-05-09T00:07:55Z
date available2017-05-09T00:07:55Z
date copyrightMarch, 2002
date issued2002
identifier issn0098-2202
identifier otherJFEGA4-27170#205_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/127024
description abstractThis paper reports the development of an experimentally validated model for pressure drop during intermittent flow of condensing refrigerant R134a in horizontal microchannels. Two-phase pressure drops were measured in five circular channels ranging in hydraulic diameter from 0.5 mm to 4.91 mm. For each tube under consideration, pressure drop measurements were first taken over the entire range of qualities from 100% vapor to 100% liquid. In addition, the tests for each tube were conducted for five different refrigerant mass fluxes between 150 kg/m2 -s and 750 kg/m2 -s. Results from previous work by the authors on condensation flow mechanisms in microchannel geometries were then used to identify data that corresponded to the intermittent flow regime. A pressure drop model was developed for a unit cell in the channel based on the observed slug/bubble flow pattern for these conditions. The unit cell comprises a liquid slug followed by a vapor bubble that is surrounded by a thin, annular liquid film. Contributions of the liquid slug, the vapor bubble, and the flow of liquid between the film and slug to the pressure drop were included. Empirical data from the literature for the relative length and velocity of the slugs and bubbles, and relationships from the literature for the pressure loss associated with the mixing that occurs between the slug and film were used with assumptions about individual phase friction factors, to estimate the total pressure drop in each unit cell. A simple correlation for non-dimensional unit-cell length based on slug Reynolds number was then used to estimate the total pressure drop. The results from this model were on average within ±13.4% of the measured data, with 88% of the predicted results within ±25% of the 77 measured data points.
publisherThe American Society of Mechanical Engineers (ASME)
titleAn Experimentally Validated Model for Two-Phase Pressure Drop in the Intermittent Flow Regime for Circular Microchannels
typeJournal Paper
journal volume124
journal issue1
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.1428327
journal fristpage205
journal lastpage214
identifier eissn1528-901X
keywordsFlow (Dynamics)
keywordsBubbles
keywordsPressure drop
keywordsSlug
keywordsMicrochannels
keywordsVapors
keywordsRefrigerants
keywordsPressure AND Condensation
treeJournal of Fluids Engineering:;2002:;volume( 124 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record