description abstractCompressors are intolerant to liquids. In reciprocating compressors with inherently large volumetric displacement rates, all modes of liquid ingestion pose a serious problem and can even result in catastrophic failures. This paper describes a simple method of estimating the cylinder pressure and “rod load” (force on the crosshead pin, in compressor terminology) in a double-acting reciprocating compressor. The results indicated that even with moderate volume of liquid present inside the cylinder, the pressure could reach values as high as four to five times its normal value with a correspondingly higher rod load.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of Liquid on a Reciprocating Compressor
typeJournal Paper
journal volume124
journal issue3
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.1491981
journal fristpage187
journal lastpage190
identifier eissn1528-8994
keywordsPressure
keywordsCompressors
keywordsCylinders
keywordsStress AND Pistons
treeJournal of Energy Resources Technology:;2002:;volume( 124 ):;issue: 003