description abstractResearch on pumps, particularly those for transporting cryogenic fluids, is very expensive. Rocketdyne has tested pumps with air as the working fluid and has found that a very good correlation exists between air test data and liquid test data. This paper gives a description of the air rigs used by Rocketdyne and compares the data taken in air with data taken in water, LOX, RP-1, and liquid hydrogen. Also presented is the effect of tip clearance on the head of an axial-flow pump as determined from air tests.
publisherThe American Society of Mechanical Engineers (ASME)
titleTesting Pumps in Air
typeJournal Paper
journal volume90
journal issue2
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3609173
journal fristpage97
journal lastpage104
identifier eissn0742-4795
keywordsPumps
keywordsTesting
keywordsFluids
keywordsClearances (Engineering)
keywordsAxial flow
keywordsHydrogen AND Water
treeJournal of Engineering for Gas Turbines and Power:;1968:;volume( 090 ):;issue: 002