description abstractNumerical simulations of the turbulent flow in an asymmetric two-dimensional diffuser are carried out using three commercial CFD codes: CFX, Fluent, and Star-CD. A low-Reynolds number k-ε model with damping functions and the four-equation v′2−f model are used; the first one is available as a standard feature in all the codes, the v′2−f model was implemented using the User Defined Routines. The flow features a large recirculating zone due to the adverse pressure gradient in the diffuser; the v′2−f predictions agree very well with the experiments both for the mean velocity and the turbulent kinetic energy. The length of the separation bubble is also computed within 6 percent of the measured value. The k-ε calculations do not show any recirculation and the agreement with the measurements is very poor. The three codes employed show very similar characteristics in terms of convergence and accuracy; in particular, the results obtained using the v′2−f are consistent in all the codes, while appreciable differences are obtained when the k-ε is employed.
publisherThe American Society of Mechanical Engineers (ASME)
titlePredictions of a Turbulent Separated Flow Using Commercial CFD Codes
typeJournal Paper
journal volume123
journal issue4
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.1400749
journal fristpage819
journal lastpage828
identifier eissn1528-901X
keywordsFlow (Dynamics)
keywordsTurbulence
keywordsComputational fluid dynamics AND Equations
treeJournal of Fluids Engineering:;2001:;volume( 123 ):;issue: 004