description abstractThe short- and long-term successes of tibial cementless implants depend on the initial fixation stability often provided by posts and screws. In this work, a metallic plate was fixed to a polyurethane block with either two bone screws, two smooth-surfaced posts, or two novel smooth-surfaced posts with adjustable inclinations. For this last case, inclinations of 0, 1.5, and 3 deg were considered following insertion. A load of 1031 N was eccentrically applied on the plate at an angle of ∼14 deg, which resulted in a 1000 N axial compressive force and a 250 N shear force. The response was measured under static and repetitive loading up to 4000 cycles at 1 Hz. The measured results demonstrate subsidence under load, lift-off on the unloaded side, and horizontal translation of the plate specially at the loaded side. Fatigue loading increased the displacements, primarily during the first 100 cycles. Comparison of various fixation systems indicated that the plate with screw fixation was the stiffest with the least subsidence and liftoff. The increase in post inclination from 0 to 3 deg stiffened the plate by diminishing the liftoff. All fixation systems demonstrated deterioration under repetitive loads. In general, the finite element predictions of the experimental fixation systems were in agreement with measurements. The finite element analyses showed that porous coated posts (modeled with nonlinear interface friction with and without coupling) generated slightly less resistance to liftoff than smooth-surfaced posts. In the presence of porous coated posts, Coulomb friction greatly overestimated the rigidity by reducing the liftoff and subsidence to levels even smaller than those predicted for the design with screw fixation. The sequence of combined load application also influenced the predicted response. Finally, the finite element model incorporating measured interface friction and pull-out responses can be used for the analysis of cementless total joint replacement systems during the post-operation period.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental and Finite Element Comparison of Various Fixation Designs in Combined Loads
typeJournal Paper
journal volume123
journal issue5
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.1395572
journal fristpage391
journal lastpage395
identifier eissn1528-8951
keywordsScrews
keywordsStress
keywordsUrethane elastomers
keywordsShear (Mechanics)
keywordsDesign
keywordsFinite element analysis
keywordsForce
keywordsFriction
keywordsFinite element model
keywordsCompression
keywordsFatigue
keywordsMeasurement
keywordsCycles
keywordsCoulombs
keywordsStability
keywordsArthroplasty AND Surgical screws
treeJournal of Biomechanical Engineering:;2001:;volume( 123 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record