Show simple item record

contributor authorS. Bolpaire
contributor authorJ. P. Barrand
date accessioned2017-05-09T00:00:39Z
date available2017-05-09T00:00:39Z
date copyrightAugust, 1999
date issued1999
identifier issn0094-9930
identifier otherJPVTAS-28392#291_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/122721
description abstractThe operational range and the performances of pumps are limited by the occurrence of backflow and prerotation in the suction pipe as the flow rate is reduced. This paper presents the study of static pressure measurements and visualizations in the suction pipe, near the inlet of a centrifugal pump, at partial flow rates, in steady conditions, and during a fast start-up of the pump. The tests were carried out in water on the DERAP© test loop of the ENSAM Lille laboratory. Standard methods allowed to determine the recirculation critical flow rate. A visualization method showed that the axial extent of the recirculation and the prerotation with the flow rate is considerably reduced during a fast start-up compared to steady conditions.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental Study of the Flow in the Suction Pipe of a Centrifugal Pump at Partial Flow Rates in Unsteady Conditions
typeJournal Paper
journal volume121
journal issue3
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.2883705
journal fristpage291
journal lastpage295
identifier eissn1528-8978
keywordsSuction
keywordsPipes
keywordsFlow (Dynamics)
keywordsCentrifugal pumps
keywordsPumps
keywordsVisualization
keywordsWater AND Pressure measurement
treeJournal of Pressure Vessel Technology:;1999:;volume( 121 ):;issue: 003
contenttypeFulltext


Files in this item