Show simple item record

contributor authorJ. R. Muñoz
contributor authorE. E. Michaelides
date accessioned2017-05-08T23:59:24Z
date available2017-05-08T23:59:24Z
date copyrightDecember, 1999
date issued1999
identifier issn0195-0738
identifier otherJERTD2-26486#268_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/122033
description abstractThe values of absolute exergy and exergetic efficiency depend on the assumed values of the “reference states,” which are essentially a model of the environment of the processes and components considered. The environmental model plays an important role in any optimization process that uses any form of exergy-based analysis. This paper examines the influence of eleven previously proposed models for the environment on the absolute values of the exergy and on the exergetic efficiencies, associated with the operation of three different power plants: a methane cogeneration plant, a coal-fired plant, and a dual-flash geothermal power plant. It is observed that although there are some common characteristics in most of the values obtained from all the models, the absolute exergies and exergetic efficiencies calculated using some of these models deviate substantially from those obtained with the others. The reasons for these deviations are also examined here.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Impact of the Model of the Environment in Exergy Analyses
typeJournal Paper
journal volume121
journal issue4
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.2795993
journal fristpage268
journal lastpage276
identifier eissn1528-8994
keywordsExergy
keywordsCoal
keywordsOptimization
keywordsPower stations
keywordsCombined heat and power
keywordsExergy analysis
keywordsIndustrial plants
keywordsMethane AND Geothermal power stations
treeJournal of Energy Resources Technology:;1999:;volume( 121 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)