Show simple item record

contributor authorC. E. Miller
contributor authorM. A. Vanni
contributor authorL. A. Taber
contributor authorB. B. Keller
date accessioned2017-05-08T23:52:44Z
date available2017-05-08T23:52:44Z
date copyrightNovember, 1997
date issued1997
identifier issn0148-0731
identifier otherJBENDY-25981#445_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/118281
description abstractThe first stress–strain measurements on embryonic cardiovascular tissue are described here, obtained from cyclic uniaxial loading of the primitive Ventricle. An excised ventricular segment from Hamburger/Hamilton stage-16 or stage-18 chicks (2-1/2 and 3 days of a 21-day incubation period) was mounted longitudinally between two small wires in oxygenated Krebs–Henseleit cardioplegia solution. One wire was attached to an ultrasensitive force transducer and the other to a Huxley micromanipulator controlled by remote motor drive. A real-time video tracking system calculated three myocardial surface strains based on the positions of three surface markers while the heart was deformed in a triangular wave pattern. Force transducer output was filtered, digitally sampled, and stored with strains and time. Results were plotted as strain (longitudinal, circumferential, shear, and principal) versus time, stress versus time, and stress versus longitudinal strain. The stress–strain curves were nonlinear, even at low strain levels. The hysteresis loops were large; mean hysteresis energy as a proportion of total cycle stored strain energy was 36 percent (stage 16) and 41 percent (stage 18). We created a finite element model of the ventricle and fit the model behavior to the experimental behavior to determine parameters for a stage-18 pseudoelastic strain-energy function of exponential form. The calculated exponential parameter is significantly lower than that found in corresponding uniaxial studies of mature myocardium, possibly indicating the lower fiber content of the immature tissue. The results of this study are the first step in characterizing material properties for comparisons with later developmental stages and with impaired and altered myocardium. The long-term goal is to aid in identifying the biomechanical factors regulating growth and morphogenesis.
publisherThe American Society of Mechanical Engineers (ASME)
titlePassive Stress–Strain Measurements in the Stage-16 and Stage-18 Embryonic Chick Heart
typeJournal Paper
journal volume119
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.2798292
journal fristpage445
journal lastpage451
identifier eissn1528-8951
keywordsStress
keywordsStrain measurement
keywordsMyocardium
keywordsForce
keywordsWire
keywordsBiological tissues
keywordsTransducers
keywordsCardiovascular system
keywordsCycles
keywordsFinite element model
keywordsMotor drives
keywordsBiomechanics
keywordsWaves
keywordsShear (Mechanics)
keywordsStress-strain curves
keywordsMaterials properties AND Fibers
treeJournal of Biomechanical Engineering:;1997:;volume( 119 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record