Show simple item record

contributor authorT. Sawa
contributor authorT. Hirose
contributor authorY. Nakagomi
date accessioned2017-05-08T23:51:26Z
date available2017-05-08T23:51:26Z
date copyrightFebruary, 1996
date issued1996
identifier issn0094-9930
identifier otherJPVTAS-28365#115_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/117588
description abstractAn experimental and analytical study was made on a bolted connection subjected to thermal loading. The connection consists of an aluminum alloy tapered hub flange and a flat cover, including a gasket fastened by steel bolts and nuts. Temperature distribution in the connection was measured with thermocouples, and the axial bolt force, the maximum bolt stress, and the hub stress were measured by strain gages under a thermal condition that theinner surface of the flanges was heated and the outer surfaces of the flanges and the cover were held at room temperature. Finite difference analysis was made to obtain the temperature distributions in the connection due to a transient thermal condition. This paper demonstrates the method for obtaining an increment in axial bolt force and the maximum bolt stress. In all cases, the analytical results were fairly consistent with the experimental results.
publisherThe American Society of Mechanical Engineers (ASME)
titleBehavior of a Tapered Hub Flange With a Bolted Flat Cover in Transient Temperature Field
typeJournal Paper
journal volume118
journal issue1
journal titleJournal of Pressure Vessel Technology
identifier doi10.1115/1.2842153
journal fristpage115
journal lastpage120
identifier eissn1528-8978
keywordsTemperature
keywordsFlanges
keywordsStress
keywordsTemperature distribution
keywordsForce
keywordsThermocouples
keywordsStrain gages
keywordsGaskets
keywordsSteel AND Aluminum alloys
treeJournal of Pressure Vessel Technology:;1996:;volume( 118 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record