Show simple item record

contributor authorB. J. Azzopardi
contributor authorJ. C. F. Teixeira
date accessioned2017-05-08T23:44:31Z
date available2017-05-08T23:44:31Z
date copyrightDecember, 1994
date issued1994
identifier issn0098-2202
identifier otherJFEGA4-27090#792_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/113758
description abstractPhase anemometry and laser diffraction techniques have been employed to measure drop sizes in annular two-phase flow. The former technique also provides drop velocities. When converted to the same basis, the drop size distributions from the two techniques are in agreement. Drop velocities were 20 percent below the corresponding local velocities for the gas. Standard deviations of the drop velocities were 10 to 65 percent higher than those for the gas.
publisherThe American Society of Mechanical Engineers (ASME)
titleDetailed Measurements of Vertical Annular Two-Phase Flow—Part I: Drop Velocities and Sizes
typeJournal Paper
journal volume116
journal issue4
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.2911851
journal fristpage792
journal lastpage795
identifier eissn1528-901X
keywordsMeasurement
keywordsDrops
keywordsTwo-phase flow
keywordsDiffraction AND Lasers
treeJournal of Fluids Engineering:;1994:;volume( 116 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record