Recirculation in an Annular-Type Jet Pump
| contributor author | Donald F. Elger | |
| contributor author | Chyr P. Liou | |
| contributor author | Sam. J. Taylor | |
| date accessioned | 2017-05-08T23:44:30Z | |
| date available | 2017-05-08T23:44:30Z | |
| date copyright | December, 1994 | |
| date issued | 1994 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-27090#735_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/113749 | |
| description abstract | For some annular-type jet pump applications, it is important to avoid formation of a recirculation zone in the mixing region. The goals of this research were to find (i) when recirculation occurs and (ii) the size and location of the resulting recirculation zone. Experiments were performed using air in a straight-walled, annular-type, ducted jet. Area ratio Aj /As varied from 0.39 to 0.89; here, A is flow area, and j and s identify the jet and secondary flows, respectively. Data showed that recirculation correlates with J, where J ≈ Pj /(Pj + Ps ), and P is rate of momentum. For the area ratios studied, recirculation begins when J exceeds a value ranging from 0.89 to 0.94. This paper also presents data showing the recirculation zone boundaries and presents a discussion of jet pump design. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Recirculation in an Annular-Type Jet Pump | |
| type | Journal Paper | |
| journal volume | 116 | |
| journal issue | 4 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.2911843 | |
| journal fristpage | 735 | |
| journal lastpage | 740 | |
| identifier eissn | 1528-901X | |
| keywords | Jet pumps | |
| keywords | Flow (Dynamics) | |
| keywords | Momentum AND Design | |
| tree | Journal of Fluids Engineering:;1994:;volume( 116 ):;issue: 004 | |
| contenttype | Fulltext |