Show simple item record

contributor authorM. Bogema
contributor authorP. L. Monkmeyer
date accessioned2017-05-08T23:41:57Z
date available2017-05-08T23:41:57Z
date copyrightSeptember, 1960
date issued1960
identifier issn0098-2202
identifier otherJFEGA4-27224#729_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/112278
description abstractTests have been conducted to determine the usefulness of the quadrant edge orifice as a fluid-metering device for low Reynolds number flow. As a result of numerous laboratory tests to determine the behavior of the discharge coefficient with changing Reynolds number, the following are discussed: The range of constant discharge coefficient, reproducibility of orifice plates, diameter ratio effects, upstream roughness effects, reinstallation effects, and effects of pressure tap location.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Quadrant Edge Orifice—A Fluid Meter for Low Reynolds Numbers
typeJournal Paper
journal volume82
journal issue3
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3662726
journal fristpage729
journal lastpage733
identifier eissn1528-901X
keywordsFlowmeters
keywordsReynolds number
keywordsDischarge coefficient
keywordsPressure
keywordsFlow (Dynamics)
keywordsFluids
keywordsSurface roughness AND Plates (structures)
treeJournal of Fluids Engineering:;1960:;volume( 082 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record